documents:mtb-etc:mtb-etcinstall [2022/10/14 12:05]
dmarkovitch
documents:mtb-etc:mtb-etcinstall [2022/10/14 12:06] (current)
dmarkovitch removed Deg2
Line 442: Line 442:
 Temperature transducers 691203/202-300 have a temperature measurement Temperature transducers 691203/202-300 have a temperature measurement
 range of +5 to 300°F. Temperature transducers 691212/213-450 have a temperature range of -40 to +450°F. During configuration, the 691202/203-300 range of +5 to 300°F. Temperature transducers 691212/213-450 have a temperature range of -40 to +450°F. During configuration, the 691202/203-300
-transducers are selected as Deg1 Type, the 691212/213-450 transducers are +transducers are selected as Deg1 Type, and the 691212/213-232 transducers are selected by choosing Deg3 type. The three wires from the transducers are: +5
-selected by choosing Deg2 Type, and the 691212/213-232 transducers are selected by choosing Deg3 type. The three wires from the transducers are: +5+
 volt excitation, temperature output voltage, and minus return. These wires connect directly to the Terminal Module using cable assembly P/N 693008-x. volt excitation, temperature output voltage, and minus return. These wires connect directly to the Terminal Module using cable assembly P/N 693008-x.