 ===== - UNDERSTANDING THE HOME SCREEN ===== ===== - UNDERSTANDING THE HOME SCREEN =====
 ==== - TOP SCREEN ==== ==== - TOP SCREEN ====
-{{ :documents:ngi-5000-logic:top_screen.jpg?400 |}}+{{ :documents:ngi-5000-logic:top_screen.jpg?400|}}
  
 A top screen is for a view of information and can be changed if other quick view information is desired. A top screen is for a view of information and can be changed if other quick view information is desired.
 +
 +----
 +
 +The FIRING message is displayed when the ignition begins firing. Additional data is provided
 +on this screen to describe the selected mode of operation for the ignition. The energy mode
 +(E1,E2,E3) and the single-strike / multi-strike type (S or M)
 +
 +
 +----
 +
 +The STALLED message is displayed when a loss of rotation is detected after the ignition is
 +firing and neither a SHUTDOWN or FAULT has occurred. This signifies that the engine has
 +stopped without any detected cause from the ignition system.
 +
 +
 +----
 +
 +The SHUTDOWN screen will supersede all other home displays if the shutdown input is
 +grounded or if the shutdown input was grounded and the engine has not stopped rotating.
 +This screen indicates that the ignition is not firing because the shutdown input was activated
 +to shutdown the engine. The Fire Confirm Out switch will change state (switch opens) and
 +the other outputs will function as described above based on the existence of faults or
 +warnings.
 ==== - BOTTOM SCREEN ==== ==== - BOTTOM SCREEN ====
  
Line 72: Line 95:
 {{ :documents:ngi-5000-logic:bottom_screen_all.jpg?600|}} {{ :documents:ngi-5000-logic:bottom_screen_all.jpg?600|}}
  
 +Interfacing with the bottom screen is dynamic with a touch interface. Buttons are available to open additional windows, and to activate different features, as well as the ability to scroll on the screen.
  
 ---- ----
Line 103: Line 127:
  
 {{ :documents:ngi-5000-logic:bottom_screen_2.jpg?300|}} {{ :documents:ngi-5000-logic:bottom_screen_2.jpg?300|}}
 +Global retard is an adjustment affecting the timing of all cylinders equally. This adjustment
 +can be equated to the manual timing switch of the Altronic II-CPU system. Adjustments
 +made as described below will be in effect until another adjustment is made.
 +
  
 ---- ----
Line 110: Line 138:
 ---- ----
 {{ :documents:ngi-5000-logic:manual_retard.jpg?300|}} {{ :documents:ngi-5000-logic:manual_retard.jpg?300|}}
 +The increment of timing change is dependent on the number of holes or teeth being sensed. 
 +The minimum timing change is equal to "90/N" where N = no. of holes or teeth. EXAMPLE: 
 +For 360 holes, the minimum timing change increment is 90/360 = 0.25 degrees.
 ===== - SELECTION OF GLOABL TIMING MODES ===== ===== - SELECTION OF GLOABL TIMING MODES =====
 {{ :documents:ngi-5000-logic:timing_all.jpg?300|}} {{ :documents:ngi-5000-logic:timing_all.jpg?300|}}
 +Several options exist with regard to global timing modes. Once the global timing mode menu
 +is entered as described below, the status of each option can be viewed and changed.
  
 ---- ----
Line 120: Line 152:
  
 {{ :documents:ngi-5000-logic:one_step_retard.jpg?300|}} {{ :documents:ngi-5000-logic:one_step_retard.jpg?300|}}
 +selection can increase or decrease the one-step retard value. The default 
 +configuration selects one step retard to be controlled by the Misc Input terminal. The 
 +additional retard would be implemented when the input is grounded.
 ---- ----
 {{ :documents:ngi-5000-logic:rpm_retard.jpg?300|}} {{ :documents:ngi-5000-logic:rpm_retard.jpg?300|}}
 +e selection can enable or disable the pre-configured retard curve controlled 
 +internally by engine RPM.
 ---- ----
 {{ :documents:ngi-5000-logic:4-20.jpg?300|}} {{ :documents:ngi-5000-logic:4-20.jpg?300|}}
 +selection can enable or disable the pre-configured retard curve controlled by
 +the 4-20 mA current loop input. The choices are ON and OFF,
  
 ---- ----
 {{ :documents:ngi-5000-logic:serial_retard.jpg?300|}} {{ :documents:ngi-5000-logic:serial_retard.jpg?300|}}
 +selection can enable or disable the additional retard value controlled by the 
 +serial port.
 ===== - SETUP CONTROL OPTIONS ===== ===== - SETUP CONTROL OPTIONS =====
-{{ :documents:ngi-5000-logic:energy_level.jpg?400|}}+{{ :documents:ngi-5000-logic:energy_level.jpg?300|}}
  
 ---- ----
-{{ :documents:ngi-5000-logic:multistrike.jpg?400|}}+{{ :documents:ngi-5000-logic:multistrike.jpg?300|}}
  
 ---- ----
-{{ :documents:ngi-5000-logic:overspeed.jpg?400|}}+{{ :documents:ngi-5000-logic:overspeed.jpg?300|}}
  
 ---- ----
-{{ :documents:ngi-5000-logic:offsets.jpg?400|}}+{{ :documents:ngi-5000-logic:offsets.jpg?300|}}
  
 ---- ----
-{{ :documents:ngi-5000-logic:test_mode.jpg?400|}}+{{ :documents:ngi-5000-logic:test_mode.jpg?300|}}
  
 ---- ----
-{{ :documents:ngi-5000-logic:ee_protection.jpg?400|}}+{{ :documents:ngi-5000-logic:ee_protection.jpg?300|}}
 ===== - NGI-5000 DIAGNOSTICS ===== ===== - NGI-5000 DIAGNOSTICS =====