documents:ngi-5000-logic:ngi5000operating [2023/02/28 10:18] rocky [7. ADJUSTING GLOBAL RETARD] |
documents:ngi-5000-logic:ngi5000operating [2023/02/28 10:23] (current) rocky [8. SELECTION OF GLOABL TIMING MODES] |
||
|---|---|---|---|
| Line 143: | Line 143: | ||
| ===== - SELECTION OF GLOABL TIMING MODES ===== | ===== - SELECTION OF GLOABL TIMING MODES ===== | ||
| {{ : | {{ : | ||
| + | Several options exist with regard to global timing modes. Once the global timing mode menu | ||
| + | is entered as described below, the status of each option can be viewed and changed. | ||
| ---- | ---- | ||
| Line 150: | Line 152: | ||
| {{ : | {{ : | ||
| + | selection can increase or decrease the one-step retard value. The default | ||
| + | configuration selects one step retard to be controlled by the Misc Input terminal. The | ||
| + | additional retard would be implemented when the input is grounded. | ||
| ---- | ---- | ||
| {{ : | {{ : | ||
| + | e selection can enable or disable the pre-configured retard curve controlled | ||
| + | internally by engine RPM. | ||
| ---- | ---- | ||
| {{ : | {{ : | ||
| + | selection can enable or disable the pre-configured retard curve controlled by | ||
| + | the 4-20 mA current loop input. The choices are ON and OFF, | ||
| ---- | ---- | ||
| {{ : | {{ : | ||
| + | selection can enable or disable the additional retard value controlled by the | ||
| + | serial port. | ||